TI-007X

Precision Ultrasonic Wall Thickness Gauge for Thin Walls
Resolution: .0001″ (0.001 mm)
Includes NIST-Traceable Calibration Certificate, CE-Certified
5-Year Warranty, Made in USA
Datalogging: NO

Description

Range with Standard Delay Line Transducer
0.0060″ – 1.000″ / 0.150 – 25.40 mm

Range with Contact Transducers
up to 36.00″ / 915.0 mm

The TI-007X is a precision ultrasonic wall thickness gauge designed for high-resolution measurements on thin-wall metal and plastics. It is packaged in a sturdy extruded aluminum housing which is sealed for excellent environmental protection assuring trouble-free use even in the toughest field and production environments.

The TI-007X has measuring range in steel from 0.0060 to 1.0000 inch, (0.15 to 25.40 mm). Using a single element delay tip transducer, the gauges will measure thin materials and automatically remove any coatings in Echo-Echo Mode (E-E) as well as automatically switch to Interface Echo Mode (I-E)when measuring thicker materials, For measurement of plastics, the user would select Plastic Mode (PLAS) and use the option Graphite Delay Line Tip (p/n X-633-0000).

Additional Measuring Modes include Differential (DIFF) where a user sets a “nominal value” and the gauge displays the ± difference between then nominal and actual wall thickness, Alarm (user-set Hi/Low Limits) trigger Hi/Lo LED’s when the measured values are out of tolerance and Velocity Mode

The TI-007X can also be used with single element contact transducers for wall thickness measurements up to 36 inches (923 mm). Although the TI-007X does not have any built-in memory, it can transfer single values (value on the display) via the USB port to a PC or compatible data collector. No Software is required.

Features

  • Includes NIST Traceable Calibration Certificate
  • Resolution of 0.0001 inch (0.001 mm)
  • Large, backlit LCD display retains last reading
  • Selectable units of inch or mm
  • Selectable Backlight ON/OFF/AUTO
  • Optional serial RS-232 or Bluetooth output
  • IP 65 Rated for protection even in the toughest field conditions
  • Operates on two (2) AA Batteries – 45 hours continuous operation
  • Powered by: 120MHz FPGA timing & 100 volt spike pulser
  • Measure Modes: Pulse-Echo (P-E), Echo-Echo (E-E), Interface Echo (I-E) and Plastics (PLAS)
  • Additional Modes Include Differential (from user-entered “nominal value”), Alarm (user-set Hi/Low Limits) and Velocity Mode
  • LCD shows Thickness Value, Velocity Setting, Gain Setting, Stability & Battery Indicators, Scan Mode, Zero and units
  • Scan mode, 100 readings/sec. Probe is slid over a large measuring area, the minimum thickness during the “scan” will be displayed
  • Calibrate to a sample of known thickness which automatically calculates the optimal acoustic velocity
  • Adjustable GAIN (AGC) in 5 steps to fine tune the gauge for use on challenging materials or applications
  • Can be used with both Single Element Delay Line and contact transducers (5 to 20MHz)
  • USB-C Data transfer cable is optional for single data point transfer
  • CE-Certified
  • Warranty: Gauge: 5 Years Probes: 90 Days
  • Made in the USA

Delay Line Tips for TI-007X

F-000-7102 1/4″ x 3/8″
for all metals
(Short)
Standard
F-000-7103 1/4″ x 1/2″
for all metals
(Long)
Standard
X-633-0000 1/4″ x 3/8″
Graphite Tip
for thin plastics
(Graphite Short)
OPTIONAL

 

Additional information

Total Measuring Range (Steel)

0.006 – 36.000 inches
0.15 – 924 mm
(depends on material and transducer/probe type)

Range with Standard Probe

0.0060-1.0000" (0.15-25.40 mm) with standard delay line transducer in steel

Resolution

0.0001" (0.001 mm) . 0.001" (0.01 mm), user-selected units and resolution

Measuring Modes

Pulse-Echo (P-E), Echo-Echo (E-E), Interface Echo (I-E) and Plastics (PLAS), Differential, Alarm, Scan and Velocity (VX)

Gain

Automatic time dependent gain (TDG) with manual override

Velocity Range

0.0120 to .7300 in/μs (305 to 18,542 m/sec)

Probe (Standard)

1/4" diameter, 15 MHz delay line transducer with cable (p/n T-402-5507)

Probes (optional)

Various Single Element Delay Line and Contact Transducers (5 to 20MHz)

Cable

4 ft. (1.2 m) with Microdot/Lemo00 connector.

Display

Multi-function 7 segment 4.5 digit liquid crystal display with Back-light

Display Backlight

Backlight is selectable on/off/auto, and selectable brightness (Lo, Med, Hi) options

Display Update Rate

10 Hz (10 updates/sec)

Output

USB single value only (no internal memory)TI-007DLX for a model with build-in memory for 40,000 values USB output

Output Optional

RS-232 and Bluetooth

Operating Temperature

-22 to 167F (-30 to 75C)

Battery Type

2x AA 1.5V alkaline, 1.2V NiCad, or 1.5V lithium AA cells (rechargeable batteries can be used)

Battery Life

Typically operates for 35 hours on alkaline and 18 hours on NiCad

Weight

11 ounces (308 grams)

Dimensions

2.5 x 5.17 x 1.25"
(64 x 131 x 32 mm)

Housing

Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed)

Housing Protection

IP65

Certifications

NIST Traceable and MIL-STD-45662A

Keypad

Sealed membrane that is resistant to both water and petroleum products
Seven or eight tactile-feedback keys

Pulse Repetition Frequency (PRF)

200 Hz (200 pulses/sec)

To Lock Settings

With gauge powered off, press and hold the "+" key while powering on the gauge
The LOCK icon will be illuminated on the Display

To unLock Settings

With gauge powered off, press and hold the "-" key while powering on the gauge
The LOCK icon will turn off

Warranty

Gauge: 5 Years
Probes: 90 Days

Reviews

There are no reviews yet.

Be the first to review “TI-007X”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

×